Large Memory Film Coating Thickness Gauge With Fe and NFe Function Uee 920
Features
● High Precise coating thickness gauge with high quality metal probes.
● Large memory to save 4 types of materials and 1560 testing values.
● Software for PC connection and data transmission, analysis.
● Two measuring methods: continuous and single.
● Two working mode: direct and batch.
● Limit setting function.
● Switch off automatically or manually.
● 3 ways for easy Calibration: by one specimen, two specimens or five specimens to finish calibration.
● Five statistics: Average, Maximum, Minimum, Testing times, Standard deviation.
● Standard delivery with 5 calibration specimens (48.5μm, 99.8μm, 249μm, 513μm, 1024μm).
● 3 years warranty and life-long services.
Measuring Materials
Magnetic Induction (Fe): Measuring the thickness of Non-magnetic coating on magnetic metal substrate, such as aluminum, chromium, copper, zinc, rubber, paint on the base of steel, iron, alloy and magnetic steel.
Eddy Current (NFe): Measuring the thickness of Non-conductive coating on non-magnetic metal substrate, such as rubber, plastic, paint, oxide on the base of aluminum, copper, zinc, tin.

Technical Parameters
|
Model No. |
Uee 920 |
|
Measuring principle |
Magnetic induction (Fe) & Eddy current (NFe) |
|
Measuring range (µm) |
0~1250μm |
|
Probe |
Changeable |
|
Shell |
Plastic |
|
Accuracy |
±(2%H+1) μm; H refers to the thickness of testing piece |
|
Minimum resolution (µm) |
0.1μm |
|
Min curvature of the min area (mm) |
Convex 1.5 Concave 9 |
|
Diameter of the min area (mm) |
Φ7 |
|
Critical thickness of substrate (mm) |
0.5 |
|
Memory |
1560 |
|
Dimensions |
163*78*33 mm |
|
Power supply |
2*AA Alkaline battery |
|
Standard Configuration |
Main Machine, probe*1 (Fe or NFe), substrate*1 (Fe or NFe), software & USB, Calibration specimens*5, Users' Manual, Qualified Certificate, AA battery*2, Packing list, Warranty card |
|
Optional Accessories |
Probes, Specimens |
Characteristics
● Using both the magnetic and eddy current method,can measure the thickness of the magnetic non-magnetic coating on metal substrates and measurable non-magnetic thickness of the conductive coating on metal substrates.
● Five statistics: Average, maximum and minimum values, test times, the standard deviation.
● Single point calibration can be used two methods of calibration and two points for calibration instrument, basic calibration method and can be used to modify the system error of measuring probe.
● Delete function: To delete a single suspicious data in measurement, Also can delete all the data, so that new measurement
● Limit set: Instrument can automatically alarm to the measured value beyond the limit.
● Under voltage instruction.
● Operation process have hum tips.
● Error prompt, screen display or hum errors
● Can be connected by installing the software and computer. It can be finished through computer operation data download after connection, Storage, printing, etc, fast and convenient.
Hot Tags: precise coating thickness gauge, China precise coating thickness gauge manufacturers, suppliers